We also can design and style and make non-normal products to meet customers’ specific requirements. Our primary merchandise are Needle Roller bearings, Cylindrical Roller Bearings, Rod finish Bearings, Spherical simple bearings, Track roller Bearings for Guideway, Roller Bearings, Mix Bearings for forklifts, Water Pump Bearings, SNR Vehicle Bearings and all sorts of Spherical Bearings. PersonnelOur income persons are nicely educated to accommodate your requests and communicate English for your comfort.
NTS sequence turbine travel counter stream cooling tower is made on foundation of counter movement fan motor cooling tower, which is utilised to preserve far more EPT and price for the finish user.
In the response turbine, h2o is total of the EPT wheel stream channel, EPT movement channel with turbo circulation pressurizing potential. All leaf fulfilled water impact at the very same time, so unEPTthe minimal drinking water head, hydraulic turbine can assure the biggest supporter of kinetic energy output. Meanwhile, counterattack turbine is outfitted with tail pipe, the function is to circulation at the eXiHu (West Lake) Dis.t of kinetic power recovery yet again. Without having any improve in circulating h2o pump electric powered, it reduces a good deal of motor electric powered decline of the standard cooling towers.
Parts Instruction
Infill
Specially designed S condition PVC infill is EPT formed of .3 thickness or far more thicker PVC movie with excellent chemical and large distortion resistance, large coefficient of heat transfer, modest wind resistance, large ventilation performance. We have distinct materials like PVC, UPVC, and PP to go well with different water temperature.
Drift Eliminator
The NSH collection cooling tower used effortless put in PVC substance drift eliminator to avoid water from splashing out of the cooling tower.
Metal Construction
Hop-dip galvanized steel framework to maintain the cooling tower wonderful functionality and EPT lifespan, very good anti-corrosion, assure the use of a lot more than fifteen a long time. Stainless metal hardware parts are also offered for possibilities if somewhere EPT situation necessary.
Air Inlet Louver
The air inlet louver is utilized of F.R.P areas which helps make the EPT life of the EPT cooling tower. For sewage water cooling tower, we will use diverse type of the air inlet louver to meet consumers specifications.
Distribution Nozzles
The distribution nozzles utilized substantial good quality A.EPT.S /PP material, straightforward to mounted on the drinking water pipe and make certain the water splashed evenly on the infill.
Product | Drinking water stream (m3/h) | Dimension (mm) |
Fan Diameter (mm) |
Head decline (kpa) |
Fat(kg) | |||
Design | Length | Width | Peak | Dry | Wet | |||
NTS-a hundred-1 | one hundred | 2200 | 2200 | 4670 | 145 | 1500 | 1130 | 2230 |
NTS-a hundred twenty five-one | a hundred twenty five | 2200 | 2200 | 4670 | a hundred forty five | 1800 | 1190 | 2300 |
NTS-150-one | a hundred and fifty | 2800 | 2800 | 4670 | a hundred forty five | 1800 | 1540 | 2970 |
NTS-175-1 | 175 | 2800 | 2800 | 4670 | one hundred forty five | 2100 | 1620 | 3040 |
NTS-two hundred-one | two hundred | 3200 | 3200 | 4670 | one hundred fifty | 2100 | 1970 | 4330 |
NTS-225-one | 225 | 3200 | 3200 | 4670 | 150 | 2400 | 2110 | 4520 |
NTS-250-one | 250 | 3600 | 3600 | 4670 | one hundred sixty | 2400 | 2650 | 5390 |
NTS-three hundred-2 | 300 | 5600 | 2800 | 4670 | one hundred forty five | 1800 | 2260 | 4460 |
NTS-350-2 | 350 | 5600 | 2800 | 4670 | one hundred forty five | 2100 | 2380 | 4600 |
NTS-four hundred-2 | 400 | 6400 | 3200 | 4670 | one hundred fifty | 2100 | 3080 | 5940 |
NTS-450-two | 450 | 6400 | 3200 | 4670 | a hundred and fifty | 2400 | 3240 | 6080 |
NTS-five hundred-2 | 500 | 7200 | 3600 | 4670 | 160 | 2400 | 3940 | 8660 |
NTS-525-three | 525 | 8400 | 2800 | 4870 | a hundred and fifty | 2100 | 4860 | 9120 |
NTS-600-three | 600 | 9600 | 3200 | 4870 | a hundred and sixty | 2100 | 5910 | 12990 |
NTS-seven hundred-four | seven hundred | 11200 | 2800 | 4870 | a hundred and fifty | 2100 | 6480 | 12160 |
NTS-800-4 | 800 | 12800 | 3200 | 4870 | 160 | 2100 | 7880 | 17320 |
NTS-900-4 | 900 | 12800 | 3200 | 4870 | 160 | 2400 | 8440 | 18080 |
NTS-one thousand-4 | 1000 | 14400 | 3600 | 4870 | one hundred seventy | 2100 | 10600 | 21560 |
FRQ:
1. Are you maker?
Answer: Indeed we are a cooling tower company situated in ZheJiang Province EPT. With eighteen several years of production and OEM services for a number of brand name of renowned cooling tower.
two. Can you give the cooling tower areas various with the specification in earlier mentioned showing type?
Solution: We can maker and freshly design for EPT orEPTbased on your provided specification and drawing or performance specifications.
three. What items are you production?
Solution: Cooling towers with its accessories (motor, steel frame, plastic components, FRP panel, PVC infill, motor, drinking water pump, motor fan, handle box for admirer)
4. What is the supply time?
Response: For round kind cooling tower below 300RT, we have stock in warehouse. Other variety cooling tower, need to production on EPT the PO. Leading time fifteen operating times.
5. What is your top quality warranty?
Reply: 1 yr for motor, two a long time for metal areas, 5 many years for FRP pannel. Free of charge areas obtainable during XiHu (West Lake) Dis.Hu (West Lake) Dis.rantee peroid.
6. How many staff functioning in your manufacturing facility?
Answer: 270 staff at the stop of 2013.
seven. Do you have any creation management method or certification for goods.
Solution: ISO 9001: 2008 quality and surroundings management program certificates. CTI certification for cooling towers.