Rexroth Hydraulic A2FM80 90 Piston Motor for Excavator

CZPT   CZPT A2FM80/ninety piston Motor for Excavator

Brueninghaus Hydromatik CZPT A2FM motor

CZPT motor A2FM5, A2FM10, A2FM12, A2FM16, A2FM23, A2FM28, A2FM32, A2FM45, A2FM56, A2FM63, A2FM80, A2FM90,
A2FM107, A2FM125, A2FM160, A2FM180, A2FM200, A2FM250, A2FM355, A2FM500, A2FM710, A2FM1000

Description  

Open circuits
Sequence sixty six, sixty three, 60
Measurement: ten 12 sixteen 23 28 32 45 56 sixty three eighty ninety 107 one hundred twenty five 160 180 two hundred 250 355 five hundred 710 a thousand
Strain: Size five Nominal strain 4550 psi (315 bar)/Peak pressure 5100 psi (350 bar)
Dimension ten to 200 Nominal stress 5800 psi (four hundred bar)/ Peak stress 6500 psi (450 bar)
Dimension 250 to 1000 Nominal stress 5100 psi (350 bar)/ Peak stress 5800 psi (400 bar)
 
The A2FM set displacement motor with axial tapered piston rotary group of bent axis layout, for hydrostatic drives in open up circuits
– For use in mobile and stationary apps places
– Output circulation is proportional to generate speed and displacement
– The travel shaft bearings are designed to give the support life anticipated in these places of operation
– Substantial power density
– Compact layout
– Substantial all round efficiency
– CZPTal conception
– One particular piece pistons with piston rings
 
CZPT Information of Brueninghaus Hydromatik CZPT A2FM motor 
Table of values (theoretical values, without efficiency and tolerances values rounded)

CZPT A2FM motor A2FM5 A2FM10 A2FM12 A2FM16 A2FM23 A2FM28 A2FM32 A2FM45
Displacement V g cm³ 4.ninety three 10.3 12 sixteen 22.9 28.1 32 forty five.six
Pace nnom rpm 5600 3150 3150 3150 2500 2500 2500 2240
Flow at nnom qV l/min 27.6 32.4 37.8 50 57 70 eighty 102
Energy Δp = 315 bar P kW 14.5
Δ p = four hundred bar P kW 21.6 twenty five 34 38 47 53 68
Torque Δp = 315 bar T Nm 24.seven
Δ p = four hundred bar T Nm 65 seventy six 101 one hundred forty five 178 203 290
Fat (approx.) m kg two.five 6 6 6 nine.five nine.five nine.5 13.5
CZPT A2FM motor A2FM56 A2FM63 A2FM80 A2FM90 A2FM107 A2FM125 A2FM160 A2FM180
Displacement V g cm³ 56.one 63 80.four 90 106.seven one hundred twenty five one hundred sixty.4 a hundred and eighty
Pace nnom rpm 2000 2000 1800 1800 1600 1600 1450 1450
Flow at nnom qV l/min 112 126 a hundred and forty four 162 a hundred and seventy two hundred 232 261
Electricity Δ p = 400 bar P kW 75 84 96 108 114 133 one hundred fifty five 174
Torque Δ p = four hundred bar T Nm 356 four hundred 511 572 678 795 1571 1145
Bodyweight (approx.) m kg eighteen eighteen 23 23 32 32 forty five 45
CZPT A2FM motor A2FM200 A2FM250 A2FM355 A2FM500 A2FM710 A2FM1000    
Displacement V g cm³ 200 250 355 500 710 one thousand    
Speed nnom rpm 1550 1500 1320 1200 1200 950    
Flow at nnom qV l/min 310 375 469 600 826 950    
Energy Δ p = 350 bar P kW 219 273 350 497 554    
Δ p = four hundred bar P kW 207    
Torque Δ p = 350 bar T Nm 1393 1978 2785 3955 5570    
Δ p = 400 bar T Nm 1272    
Bodyweight (approx.) m kg sixty six seventy three one hundred ten 155 322 336    

CZPT fluid
Ahead of commencing undertaking plHangZhou, make sure you refer to our data sheets RE 95710 (mineral oil), RE 95711 (environmentally satisfactory hydraulic fluids) and RE 95713 (HF hydraulic fluids) for comprehensive information with regards to the decision of hydraulic fluid and software conditions.
The mounted motor AA2FM is unsuitable for operation with HFA. If HFB, HFC and HFD or environmentally appropriate hydraulic fluids are getting employed, the restrictions concerning specialized knowledge and seals pointed out in RE 95711 and RE 95713 have to be noticed.
Particulars concerning the choice of hydraulic fluid
The proper selection of hydraulic fluid demands knowledge of the running temperature in relation to the ambient temperature: in an open circuit the tank temperature. The hydraulic fluid should be picked so that the functioning viscosity in the functioning temperature assortment is inside the the best possible variety (νopt.) – the shaded spot of the selection diagram. We advisable that the larger viscosity course be selected in each scenario. Case in point: At an ambient temperature of X°F (X°C) an operating temperature of 140°F (60°C) is set. In the the best possible functioning viscosity variety (νopt shaded area) this corresponds to the viscosity lessons VG forty six or VG sixty eight to be selected: VG 68.
Remember to be aware: The circumstance drain temperature, which is affected by stress and pace, is usually increased than the tank temperature. At no stage in the system may the temperature be increased than 240°C (115°C) for measurements five to two hundred or 195°F (90°C) for measurements 250 to 1000.
If the above problems can’t be maintained due to excessive functioning parameters, we advise flushing the situation at port U (size 250 to a thousand).
Lengthy-life bearing (measurements 250 to a thousand) 
For lengthy services lifestyle and use with HF hydraulic fluids. Very same external dimensions as motor with CZPT bearing. A prolonged-daily life bearing can be specified. Flushing of bearing and case by means of port U suggested.
Shaft seal ring
The provider daily life of the shaft seal ring is afflicted by the pace of the motor and the scenario drain force. It is advisable that the common, steady case drain pressure at working temperature forty five psi (3 bar) complete not be exceeded (max. permissible case drain stress to 90 psi (six bar) complete at lowered velocity). Brief-term (t < 0.1 s) pressure spikes of up to 145 psi (10 bar) absolute are permitted. The service life of the shaft seal ring decreases with an increase in the frequency of pressure spikes. The case pressure must be equal to or greater than the external pressure on the shaft seal ring.

 

Rexroth Hydraulic A2FM80 90 Piston Motor for Excavator