in Umuahia Nigeria  sales   price   shop   near me   near me shop   factory   supplier ISO 5660 ASTM E 1354 Cone Calorimeter manufacturer   best   Cost   Custom   Cheap   wholesaler

Because of to our sincerity in supplying ideal provider to our clients, knowing of your needs and overriding feeling of responsibility toward filling ordering specifications, Every approach, every single section, every single perform in EPG is demanded to be done one phase pursuing an additional, carefully and cautiously, from content assortment, reformation to producing equipment, from factors heat remedy to computerized assembly, from quality control to item inspection and testing and from buy dealing to after product sales service. Getting amassed precious encounter in cooperating with international customers,
Merchandise:
Warmth launch is the core parameters to assess the fireplace actions of components and goods TESTech’s Cone calorimeter to meet up with all eXiHu (West Lake) Dis.sting stXiHu (West Lake) Dis.Hu (West Lake) Dis.rds (incXiHu (West Lake) Dis.Hu (West Lake) Dis. ISO 5660, ASTM E 1354, NFPA 264,
CAN ULC a hundred thirty five and EPTS 476 Component fifteen), And it incEPT the system this kind of as heat launch, mass loss, smoke technology, and so forth.
This fleXiHu (West Lake) Dis.ble function is the cone calorimeter many benefits in one particular.
Cone Calorimeter take a look at theory is primarily based on the principle that the burn energy is proportional to volume of oxygen’s usage. 1KG burned oxygen will generate 13.1 MJ/kg of gasoline warmth launch. Take a look at gas heat emission, ignition timing, oxygen usage charge, CO/CO2 generation price, the fuel movement will be calculated all. Cone Calorimeter DAQ technique can help customers to simply management the whole examination. 19 quottouch EPT can assist recognize the automate tests and minimizing installation area. In addition, after users location up the digital temperature real fireplace conditions, who could also alter the sample temperature, the temperature rise time to check. This strategy is equivalent to obtain true fireplace atmosphere the take a look at final results.
Design: FTech-ISO5660
StXiHu (West Lake) Dis.Hu (West Lake) Dis.rds:
#8226 ISO 5660:
#8226 ASTM E 1354:
#8226 EPTS 476 PT. 15:
#8226 NFPA 264,
Structural features
1.one, 19-inch stXiHu (West Lake) Dis.Hu (West Lake) Dis.rd cupboard integrated layout, stylish, effortless to work
one.two, Conical Heater – 230V, 5000W, the warmth output of ~ 120 kW / m2
one.3, 19 quottouch-EPT computer controlling the entire testing approach
1.four, Automatic ignition technique, the automated measurement of the burning time
1.5, 3 pieces K type thermocouples and 3 PID temperature controller for temperature regulation
1.6, SpEPT gate – To protect the sample location prior to testing, to insure the initial measurement is secure The operator could have extra time prior to the commence of the test method to detect. For flammable sample, if there is no opening and closing mechanism, it is easy to burn prematurely. This extra time is really EPTant for the operator
1.7, The sample holEPT- sample measurement of 100mm X 100mm, thickness not exceed 50mm 50mm X50m The central portion of the sample is uncovered to the heating cone cEPTr deviation plusmn one%
one.8, WeigEPT technique – high quality is calculated by the pressure gauge load cell test, precision up to .1g. Mechanical stop fixture to steer clear of injury overweight, to guarantee that equipment EPTevity Weighing selection ~ 3kg
Ignition Program
two.one, 10kV spark ignition, with safety stop-fire devices.
two.2, Computerized ignition program Automatic timing Expire instantly flip off
Exhaust Technique
three.1, The aXiHu (West Lake) Dis.al admirer, stainless metal exhaust pipe, the diffusion plate, hoods, exhaust pipes, orifice movement meter and a thermometer composition
three.2, All the fixture is created of stainless steel to proEPT their existence. IncXiHu (West Lake) Dis.Hu (West Lake) Dis. the hood, the gas sample sampling needle, exhaust supporter (adjustable circulation, 0g / s to 50g / s, the accuracy of at least .1g / s), and
3.three, Orifice movement tester (thermocouple and differential pressure sensors). Function circulation is 24 l/s
Fuel sampling system
four.1, Gasoline sampling system incEPTs an annular sampler probe, suction pump, particulate filter, a chilly lure, exhaust valve, h2o filters and CO2 filter
four.2, A few filters Minimum filtration accuracy is .5um
4.3, Freezing cold entice Air-conditioning compressor EPT programs Managing the temperature ~ five ordmC
four.4, Suction pump, Flow price: 33L / min, EPT: seven-hundred Hg, force: 2.5 bar
four.five Drying cylinder Filter the drinking water and impurities
four.six, The stream controller to manage the inspiratory air stream
four.7, The sampler has twelve holes reverse course of fuel stream EPTuilt-in dust filter Hoods 685mm at distance
Measurement Method
5.1, Paramagnetic oxygen analyzer, variety among -twenty five% Linear reaction
five.two, With a laser method actions the smoke density, utilizing a photodiode, .5 MW helium-neon laser, primary and backup photodetectors. At the very same time with the positioning bracket and .3, .eight neutral density filter used for calibration (optional)
five.3, Substantial-precision load sensor measuring the weigEPT alter of the take a look at process the examination material. Test range -3000g, resolution .01g. The real specifications of the examination weigEPT lt500g
five.four, Temperature management method: PID temperature manage, temperature thermocouples for measuring the radiation cone three, the diameter of 1mm
5.five, Exhaust circulation: Exhaust pipe interior diameter 57mm plusmn1mm sharp edges on both sides of the strain plate to evaluate the micro-differential strain Transmitter is linked to the management technique
Calibration Program
6.one, The United States EPTed Metherm thermoEPT sort warmth flow meter – Design variety ^ 100k W / m sup2, the accuracy of heat movement meter is plusmn 3%, repeatability is plusmn .5%
6.2 EPTurner correction program – calibrate the instrument test the warmth release charge, ninety nine.5% pure methane Methane mass stream meter specific manage of the stream of methane
6.3, With a drinking water cooling technique for warmth flow meter
six.four, With a sq. calibration burner
Functioning program
seven.1, Labview management system, person-pleasant, simple to work, precise manage
7.2 Personal computer through RS485 interface conversation module and PLC interaction url for information EPT and movement handle
7.3, PID temperature manage module and EPT adjustment module hyperlinks, thermostatically controlled by a programmable controller
7.4, Signal acquisition and processing module and the air quantity manage module circuit linked by a programmable logic controller
7.5, The system provides question capabilities. The technique instantly test sample variety and temperature profile info saved in the database program
Technological parameters
eight.one, Conical heater rated EPT 5000W, heat output ~ one hundred kW/
eight.two, The sample weighing variety ~ 2000g Precision: .1g
8.three, Paramagnetic oxygen analyzer, the concentration range of to twenty five%, an oxygen analyzer is linear reaction, EPTritain Servomex oxygen sensor ten% to 90% response time of considerably less than 12s Output sound does not exceed 50ppm . Reproduce the calculated values reduce than 100ppm,
eight.4 Infrared CO2 analyzer selection: to ten% Accuracy of plusmn .01%
eight.5 Exhaust enthusiast circulation ~ 50g / s adjustable, precision .1g / s
eight.6, The compressor functions: Chilly entice: to 5 levels
8.7, EPTort diaphragm pump, stream charge: 33 l / min
eight.eight ThermoEPT sort warmth circulation meter created variety ^ 100k W / m sup2, heat flow meter accuracy is plusmn 3% Repeatability is plusmn .five%
eight.9, The stXiHu (West Lake) Dis.Hu (West Lake) Dis.rd detector shade precision plusmn 5%, output linearity (EPT) lt1%, absolute permeability lt1%
Check knowledge:
9.one, The warmth launch rate, whole oxygen intake CO2 era quantity
nine.two, Iignition time, Flue gasoline stream, C coefficient, extinguish time
9.3, The critical ignition warmth
nine.four, Mass reduction fee
nine.5, Smoke release price

  in Umuahia Nigeria  sales   price   shop   near me   near me shop   factory   supplier ISO 5660 ASTM E 1354 Cone Calorimeter manufacturer   best   Cost   Custom   Cheap   wholesaler