in Kottayam India  sales   price   shop   near me   near me shop   factory   supplier -45° C ~250° C Industry Hermetic Refrigerating & Heating Circulator manufacturer   best   Cost   Custom   Cheap   wholesaler

If you require any information or samples, remember to make contact with us and you will have our before long reply. Our products are manufactured by modern day computerized equipment and tools. Our merchandise assortment includes all varieties of helical gear, spur equipment, bevel equipment, gear rack, worm equipment, sprockets,chains, bearings. Applicationlication:
Reactor Methods Autoclaves, Pilot Techniques, Mini Plant Techniques, Scale up for Operational DeveXiHu (West Lake) Dis.Hu (West Lake) Dis.ment, Double wall reactors, Innovative-Flow Reactors, Distillation Systems, Materials Screening, Combinational Chemistry, Semi conductor Business, Vacuum Chambers.

Positive aspects amp Capabilities

  • Hermetic circulation method make confident higher accuracy of temperature and lengthen life time of circulating liquid.
  • Extensively doing work temperatures selection from -a hundred degC to 350 degCwithout cooling fluid alter
  • Smart PID temperature management
  • Higher steadiness and reproducibility of process
  • Adopted plate heat exchanger, heating pipeline to boost charge of heating amp cooling
  • Extensively cooling EPT selection from .five to 500 kW
  • EPTrilliant 4 inch, seven inch, 10 inch TFT touch EPT with graphic display can be decide on.
  • Comprehensive warning and security functions
  • Quick cooling down from higher temperature (from 300 degC).
  • Manage software is offered which can interaction in two hundred meter length. (Optional)
  • Exceptionally compact

Structure design

A entirely shut piping design, substantial performance plate warmth exchanger utilized to minimize the demand from customers for the thermal fluid uEPTzation while offering the program to attain the speedy ups and downs in temperature The EPT program is a shut liquid circulation system with a expansion of container, enlargement of the container and the liquid circulation is adiabatic, it will not in liquid circulation, only mechanical connection, reXiHu (West Lake) Dis.Hu (West Lake) Dis.dless of the temperature is a high temperature or minimal temperature, the tank temperature is minimal to sixty degC. The rewards by this design:

  • Only the heat conduction medium in the expansion container touches the oxygen in the air. (The container temperature is restricted to 60 degC), consequently, for the duration of the approach the threat of imbibing and volaEPTzation of the warmth conducting medium is lowered.
  • No volaEPTzation of the heat conducting medium at substantial temperature.
  • No need to have to adjust the warmth conducting medium. Steady handle the temperature assortment to -80 degC~a hundred ninety degC, -70 degC~220 degC, -88 degC~170 degC, -fifty five degC~250 degC, -thirty degC~300 degC without increasing the stress.

Show perform

  • All the kind of procedure control temperatures.
  • Liquid degree of the warmth conducting medium in the growth vessel.
  • Indication doing work position of EPT technique.
  • Sign functioning standing of heater.
  • Indicator functioning standing of circulation pump.
  • Temperature manage method (materials and warmth transfer medium).
  • Temperature higher limit and reduced limit can be set.
  • Temperature difference amongst jacket amp reactor content can be set.
  • Alarm when liquid is empty.
  • Refrigeration compressor can be established to operate manually or routinely.
  • Clear temperature curve displayed, it can be zoom and exported to computer.
  • Recipe treatment set screen
  • Alarm note show

Principle of process control
Change the management settings of the technique, the reaction as quickly as feasible in the approach of the method lags guiding, be the smallest system overshoot. Managed by two PID (PID is a variable in every single group) handle loop framework, known as the two sets of management loops: the principal circuit and from the circuit, the main manage loop from the loop output as the configurations. Technique with feed EPT with PV, the master PID loop procedure benefits of the PV output and feed EPT indicators as the composite of the options from the management loop, by means of such handle of the temperature gradient to make sure the precision of temperature management program.

High repeatability of benefits management

Circulation Pump
Substantial temperature resistant reduced tempera ture magnetic travel pump or a leak-free high and reduced temperature shield-driven pump, reduce the risk of system leakage. At the very same time the program has the advantages of low sound and large visitors stream.

Electronic growth valve
Broad temperature variety of dynamic temperature management system with electronic expansion valve made by Emerson company, It can check and adjust the variety of steps (~750 Actions / moment) into the motor, exact control the liquid volume from the refrigerant , EPTrove management accuracy.

Configuration application (Optional)

All dynamic temperature handle technique HRHC-Series can be related with the laptop.
You can put in and document the picture of show on the computer by means of the configuration application.

  • Interaction length considerably less than 200m.
  • Simply temperature location
  • Real time control EPT
  • Curve EPTrds
  • Software assortment
  • Alarm EPT recording

Security security
A lot of further attributes to make certain the safe procedure of the system. For the procedure to operate not generally show up in the alarm in time and shown on the contact EPT. Phase sequence, leakage safety, EPT system higher and minimal voltage defense, overload the pump, compressor overload, higher and low amount, two independent over-temperature protection, water defense, defense of the circulation line shut.

Connecting Pipe

Items Temp. assortment Interface port
Fluorine rubber hose -30~two hundred degC Phi12*sixteen Phi16*22 Phi20* 26
Metal insulation pipe -60~250 degC DN15 DN20 DN25 M24*one.five M30*one.5 M38*1.5

Day interface amp computer software
StXiHu (West Lake) Dis.Hu (West Lake) Dis.rd configuration:

  1. Inputs of PT100 temperature sensor
  2. USEPT data export interfaces
  3. RS485 interface (MODEPTUS protocol)
  4. Alarm contact output

Optional:

  1. Inputs of 4 ~ 20mA temperature measurement
  2. Inputs of 4 ~ 20mA temperature setting
  3. Ethernet interface
  4. RS232 interface (MODEPTUS protocol)
  5. Computer running application (Must be fitted with Ethernet interface)
  6. Exterior manage box with contact EPT show

Typical Technical specs:

  • Manage manner: Feed EPT PID, PLC handle
  • Temperature control: Temperature of substance and circulation liquid can be controlled and set
  • Software:20 group packages, forty five segments for each team
  • Protocol: MODEPTUS RTU / RS 485 Interface
  • Temp. sensor: Circulation medium PT100, raw substance PT100 (three measuring details) four~20mA (Optional)
  • Handle panel: 7 inches color contact EPT, temperature curve display amp report
  • Protection: With self-analysis perform freezer overload security higher-strain change, a variety of safety characteristics overload relays, thermal safety units.
  • Closed loop system: Completely shut system, no oil mist at substantial temperature, lower temperature do not take in humidity in the air, the system does not enhance the force since the high temperature, low temperature heat transfer medium in automated replenishment procedure.

-forty five degC ~250 degC Industry

Design HRHC-4A25W HRHC-4A38W HRHC-4A60W HRHC-4A95W HRHC-4A130W
Temperature selection degC -45 degC~250 degC
Temp. precision plusmn1 degC plusmn1 degC plusmn1 degC plusmn1 degC plusmn1 degC
Heating EPT 25kW 38kW 60kW 95kW 130kW
Cooling potential 250 degC 25kW 38kW 60kW 95kW 130kW
a hundred degC 25kW 38kW 60kW 95kW 130kW
20 degC 25kW 38kW 60kW 95kW 130kW
degC 25kW 38kW 60kW 95kW 130kW
-twenty degC 16kW 26kW 34kW 45kW 60kW
-35 degC four.7kW 9kW eleven.5kW 15kW 18.5kW

Circulation pump
Max110L/min
two.5EPTAR
Max150L/min
2.5EPTAR
Max250L/min
2.5EPTAR
Max250L/min
2.5EPTAR
Max250L/min
2.5EPTAR
Compressor Copeland Copeland Copeland EPTock EPTock
Evaporator KEPTRI Plate heat exchanger
Oil separator Emerson
Expansion valve Emerson
Refrigerant R-404A
Relationship measurement DN25 PN10 DN32 PN10 DN40 PN10 DN40 PN10 DN40 PN10
Drinking water-cooled sort W
(cooling drinking water at thirty degC)
7m sup3/h
1.5bar~4bar
12m sup3/h
1.5bar~4bar
17m sup3/h
one.5bar~4bar
24m sup3/h
1.5bar~4bar
32m sup3/h
one.5bar~4bar
water-cooled condenser Shell and tube exchanger (stXiHu (West Lake) Dis.Hu (West Lake) Dis.rd)
Dimension 1500*800*1600 1800*800*1600 2000*800*1650 2300*1250*1750 2300*1450*1750
WeigEPT (water cooled) 680kg 950kg 1300kg 1550kg 1880kg
EPT AC380V 50HZ
36kW (max)
AC380V 50HZ
53kW (max)
AC380V 50HZ
80kW (max)
AC380V 50HZ
122kW (max)
AC380V 50HZ
165kW (max)
Circumstance materials SUS 304 SUS 304 SUS 304 SUS 304 SUS 304

Technological Procedure

EPT

  in Kottayam India  sales   price   shop   near me   near me shop   factory   supplier -45° C ~250° C Industry Hermetic Refrigerating & Heating Circulator manufacturer   best   Cost   Custom   Cheap   wholesaler

  in Kottayam India  sales   price   shop   near me   near me shop   factory   supplier -45° C ~250° C Industry Hermetic Refrigerating & Heating Circulator manufacturer   best   Cost   Custom   Cheap   wholesaler